The Audit of Decision Provenance in Biomedical Research Agents Traces How Tool States Become Scientific Actions

A Biomni A1 replay showed silent GPU faults changed two drug screening decisions despite stable counts. Checksums found faults; state recovery needed.

The Audit of Decision Provenance in Biomedical Research Agents Traces How Tool States Become Scientific Actions

Key Takeaways

  • Silent GPU faults can change biomedical AI decisions without crashes or NaN/Inf markers, as shown by two altered hERG drug-screening decisions in Biomni A1 replay tests.
  • Aggregate screening results may appear stable while individual compound choices and testing assignments shift, meaning top-level counts can hide silent numerical problems.
  • Common checks such as finite-value and probability-range validation missed the fault sources, but checksums on linear layers detected all 16 sources at a 25.8% runtime cost.
  • Replacing faulty prediction files did not undo already-formed decisions; restoring the agent’s execution state and supplying certified values recovered all 39 changed decisions.
  • The authors are preparing Aritheia, a GPU numerical reliability testing tool, and are recruiting independent testers who can provide GPU, driver, CUDA, and PyTorch details.

Silent GPU Faults Changed 2 Drug Screening Decisions in Biomni A1

The Audit of Decision Provenance in Biomedical Research Agents Traces How Tool States Become Scientific Actions

Meta description: Researchers show silent GPU faults changed Biomni A1 drug screening decisions, and the team now preparing Aritheia seeks testers for GPU numerical reliability.

Tags: Silent GPU faults, Biomni A1, Aritheia, drug screening, AI reliability

Featured image: Abstract friendly illustration of a GPU circuit quietly altering a chemical decision path, no real people, no logos, no text.

Silent GPU faults are calculation errors that return wrong values without a crash and without NaN / Inf markers. The authors of the Biomni A1 project page reported that such faults changed 2 drug-screening decisions in a replay test. For developers, researchers, and readers who rely on AI agents for scientific screening, the finding shows that a stable-looking result can still hide a shifted decision.

What changed in the hERG screening task

The reported test replayed captured faulty tool outputs into a hERG cardiac safety screening task. The task used the native Biomni A1 agent, and the agent itself ran on healthy hardware. That setup separated the effect of the faulty outputs from the condition of the machine running the agent.

The Audit of Decision Provenance in Biomedical Research Agents Traces How Tool States Become Scientific Actions

In the benchmark, 2 compounds, K12252 and K1461, were labeled as hERG blockers. The agent assigned them to advance without testing. That differed from the reference decision to perform patch clamp testing. Each of those changes recurred in all three repeats of its affected source.

The shortlist looked stable while choices moved

The total number of blockers in the shortlist did not shift. It still contained 351 labeled blockers out of 402 compounds. The aggregate count stayed the same, but the selected compounds and their testing assignments changed.

That distinction matters. A screening report can look consistent at the top level while the decision path behind individual compounds has moved. For readers watching AI agents make scientific recommendations, the visible count may not be enough to detect a silent numerical problem.

Checks that missed the fault

The project compared different ways to detect the issue. Checks of data integrity, finite values and probability ranges flagged 0/16 fault sources. In other words, those checks did not point to the problematic inputs.

Checksums on linear layers, a common building block in neural models, flagged 16/16 sources. The detection method therefore succeeded on the tested sources, but it carried a cost. On the measured workload, streaming verification added 25.8% to the time required for the native forward pass.

The Audit of Decision Provenance in Biomedical Research Agents Traces How Tool States Become Scientific Actions

Recovering the decision needed more than the file

The test also examined what happens after a faulty value has already been read. Replacing the prediction file after the agent had read faulty values recovered 0/39 changed decisions. Fixing the output record did not undo the decision the agent had already formed.

A different recovery path worked better. Restoring the execution state saved before that read and supplying certified values recovered 39/39 changed decisions. The execution state is the agent’s internal running context, including the values and intermediate decisions already shaped by the faulty output.

Selected SciFact examples show a related separation. Agents can return the same verdict while reading or citing different evidence. The authors’ takeaway is practical: fixing a tool output may not undo decisions already formed from it. Recovery also needs to address the execution state that depends on those values.

What comes next

The project page is https://intosyn.github.io/BioAgent-DF/. The authors say they are preparing to release Aritheia, a tool for testing GPU numerical reliability. They are looking for independent testers.

Interested testers are asked to reply with their GPU model and driver, CUDA and PyTorch versions. The authors say they welcome both runs with no detected anomalies and reproducible mismatches.